    ClinMax™ Human CXCL10/IP-10 ELISA Kit is a ready-to-use immunoassay kit, specifically designed to quantitate natural and recombinant human CXCL10/IP10 that is present in biological samples, such as human serum, plasma, and cell culture supernatants. Our ClinMax™ ELISA Kit provides several benefits:
    1. Standards to calibrate with NIBSC/WHO standards for comparable results.
    2. Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
    3. High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
    4. Simplified and straightforward protocols and ready-to-use reagents to save assay time.
  • Application

    The kit is developed for quantitative detection of natural and recombinant human CXCL10/IP10 in serum, plasma and cell culture supernatants.

    It is for research use only.

  • Workflow
     CXCL10 Workflow
    Key Features
    AnalyteCXCL10/IP-10
    Assay TypeSandwich-ELISA
    ReactivityHuman
    Sensitivity<31.25pg/mL
    Range31.25 pg/mL-2000 pg/mL
    Assay Time2 hr 45 min
    Sample TypeCell Culture Supernatants, Plasma, Serum.
    Sample volume50 uL
    Format96-wells plate breakable into 12 x 8 wells strips

    Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.

  • Storage
    Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.
Typical Data Please refer to DS document for the assay protocol.
 CXCL10 TYPICAL DATA

For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of CXCL10/IP-10 is less than 31.25 pg/mL.

Validation
Intra-Assay Statistics

Ten replicates of each of 4 samples containing different CXCL10/IP-10 concentrations were tested in one assay. Acceptable criteria: CV<10%.

 CXCL10 INTRA-ASSAY STATISTICS
Inter-Assay Statistics

Five samples containing different concentrations of CXCL10/IP-10 were tested in independent assays. Acceptable criteria: CV<15%.

 CXCL10 INTER-ASSAY STATISTICS
Recovery

Recombinant CXCL10/IP-10 was spiked into 3 human serum samples, and then analyzed. The average recovery of CXCL10/IP-10 for serum samples is 101.5%.

 CXCL10 RECOVERY
Materials Provided
IDComponentsSize
CEA028-C01Pre-coated Anti-IP-10 Antibody Microplate1 plate
CEA028-C02Human IP-10 Standard163 ug×2
CEA028-C03Biotin-Anti-IP-10 Antibody Con. Solution100 μL
CEA028-C04Biotin-Antibody Dilution Buffer8 mL
CEA028-C05Streptavidin-HRP Con. Solution500 μL
CEA028-C06Streptavidin-HRP Dilution Buffer15 mL
CEA028-C0720× Washing Buffer50 mL
CEA028-C08Sample Dilution Buffer15 mL×2
CEA028-C09Substrate Solution12 mL
CEA028-C10Stop Solution6 mL
  • Clinical and Translational Updates

Comments (0)


Voraussichtlicher Liefertermin für vorrätige Produkte: 2 Arbeitstage

Price(EUR) : €500.00

Promotion & Exhibitions



Drug Development Status

  • Number of Launched Drugs:0 Details
  • Number of Drugs in Clinical Trials:2 Details
  • Latest Research Phase:Phase 2 Clinical

Datasheet & Documentation

Request for DMF
DMF (Drug Master File)

Related Products

New Product Launch

Questions & Comments

This web search service is supported by Google Inc.

totop

Nachricht schicken