Product Details
Synonyms
CD33, SIGLEC3, gp67
Source
PE-Labeled Human Siglec-3, His Tag (CD3-HP2E3) is produced via site-specific conjugation of PE to Human Siglec-3, His Tag under optimal conditions with a proprietary technology. Human Siglec-3, His Tag is expressed from human 293 cells (HEK293). It contains AA Asp 18 - His 259 (Accession # AAH28152.1).
Predicted N-terminus: Asp 18
Request for sequenceMolecular Characterization

Other Tags and Version Biotin & Other Labeled Version
This protein carries a polyhistidine tag at the C-terminus.
The protein has a calculated MW of 29.4 kDa.
Conjugate
PE
Excitation Wavelength: 488 nm / 561 nm
Emission Wavelength: 575 nm
Application
Evaluation of anti-CD33 CAR expression by flow cytometry. Please note that this product is NOT compatible to streptavidin detection system.
Formulation
Lyophilized from 0.22 μm filtered solution in PBS, 0.5% BSA, pH7.4 with trehalose as protectant.
Contact us for customized product form or formulation.
Reconstitution
Please see Certificate of Analysis for specific instructions.
For best performance, we strongly recommend you to follow the reconstitution protocol provided in the CoA.
Storage
For long term storage, the product should be stored at lyophilized state at -20°C or lower.
Please protect from light and avoid repeated freeze-thaw cycles.
This product is stable after storage at:
- -20°C to -70°C for 12 months in lyophilized state;
- -70°C for 3 months under sterile conditions after reconstitution.
ACRO Quality Management System
Customers Also Viewed
Performance Data
Bioactivity-FACS

5e5 of anti-Siglec-3 CAR-293 cells were stained with 100 μL of 1:50 dilution (2 μL stock solution in 100 μL FACS buffer) of PE-Labeled Human Siglec-3, His Tag (Cat. No. CD3-HP2E3) and negative control protein respectively. PE signal was used to evaluate the binding activity (QC tested).
Protocol
Customer Reviews Writing Reviews
E***g2023-01-18Likes
We purchased this reagent for use in detecting CD33 CAR expression and it worked as advertised. The PE signal gave great separation by flow cytometry and allowed for the clear detection of CAR expression on the surface of our cells. The product page states that the CD33 PE reagent is incompatible with streptavidin-biotin detection systems. When we tried to co-stain with another biotinylated reagent, subsequent application of streptavidin-APC resulted in high non-specific APC staining. This could be avoided by staining with CD33 PE after all other staining steps have been completed.
S***s2023-01-12Likes
We purchased this antibody to use for flow cytometry on a client study, who specifically requested Acro antibodies! They are reliable and have continued to be one of our top providers of antibodies. We typically use multiple fluorescent antibodies with various protein targets and fluorophores at once for flow cytometry panels in human and mouse tissues, and Acro antibodies have always given us a great readout.
Background
Recent Advances
- English Name:
Myeloid cell surface antigen CD33
- Category:
- Approved Drugs:
1 Details
- Drugs in Clinical Trials:
44 Details
- Highest Development Stage:
Approved