Human IL-2 ELISA Kit

Customer Reviews
Cat. No. / Size
Price
Qty
CRS-B008-96tests
$515.00
CRS-B008-480tests (96tests X 5)
$2310.00
ETA of in-stock products:2 business days

Product Details

  • Product Overview

    Human IL-2 ELISA Kit is a ready-to-use immunoassay kit, specifically designed to quantitate natural and recombinant human IL-2 that is present in biological samples, such as human serum, plasma, and cell culture supernatants. Our ELISA Kit provides several benefits:

    1. Standards to calibrate with NIBSC/WHO standards for comparable results.
    2. Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
    3. High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
    4. Simplified and straightforward protocols and ready-to-use reagents to save assay time.

  • Product Specifications

    Assay Type
    Sandwich-ELISA
    Analyte
    IL-2
    Format
    96-wells plate breakable into 12 x 8 wells strips
    Reactivity
    Human
    Sensitivity
    5.0 pg/mL
    Assay Time
    1.75 hr
    Sample volume
    50 μL
    Range
    6.25 pg/mL-800 pg/mL
    Sample Type
    Cell Culture Supernatants, Plasma, Serum.
    NIBSC Code
    86/500

    Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.

  • Application

    The kit is developed for quantitative detection of natural and recombinant human IL-2 in serum, plasma and cell culture supernatants.

    It is for research use only.

  • Workflow

    IL-2 Workflow

  • Storage

    Unopened kit should be stored at 2℃-8℃ upon receiving. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    CRB008-C01
    Pre-coated Anti-IL-2 Antibody Microplate
    1 plate
    CRB008-C02
    Human IL-2 Standard
    25 μg×2
    CRB008-C03
    Biotin-Anti-IL-2 Antibody Con. Solution
    100 μL
    CRB008-C04
    Biotin-Antibody Dilution Buffer
    8 mL
    CRB008-C05
    Streptavidin-HRP Con. Solution
    500 μL
    CRB008-C06
    Streptavidin-HRP Dilution Buffer
    15 mL
    CRB008-C07
    20×Washing Buffer
    50 mL
    CRB008-C08
    1×Dilution Buffer
    15 mL×2
    CRB008-C09
    Substrate Solution
    12 mL
    CRB008-C10
    Stop Solution
    6 mL
  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Typical Data 

    Please refer to DS document for the assay protocol.

     IL-2 TYPICAL DATA

    For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of IL-2 is less than 5.0pg/mL.

Validation
  • Sample Values

    Serum Sample: two hundred and forty samples from healthy volunteers were tested for the presence of human IL-2 concentration in the assay. One hundred and eighty-four samples were detectable. No medical histories were available for the donors used in this study.

     IL-2 SAMPLE VALUES
  • Matrix Effect

    Six types of materials were tested to observe if there were matrix effect (interference). If the concentration of bilirubin (simulated jaundice) is less than 20 mg/dL, the concentration of hemoglobin (simulated hemolysis) is less than 3500 mg/dL, the concentration of triglyceride (simulated lipid blood) is less than 2.0 g/L, Heparin concentration is less than 40U/mL, EDTA concentration is less than 4 mg/mL, and Sodium Citrate Plasma concentration is less than 40 mg/mL, testing results will not be affected.

     IL-2 MATRIX EFFECT
  • Dilution Linearity

    High concentrations of human IL-2 serum samples were diluted with 1:2, 1:4, and 1:8 ratios for gradient dilution to evaluate the linearity of the assay. In the serum samples, the average detection rate of IL-2 was 97.38%.

     IL-2 DILUTION LINEARITY
  • Intra-Assay Statistics

    Ten replicates of each of three samples containing different IL-2 concentrations were tested in one assay. Acceptable criteria: CV<10%.

     IL-2 INTRA-ASSAY STATISTICS
  • Inter-Assay Statistics

    Three samples containing different concentrations of IL-2 were tested in the independent assays. Acceptable criteria: CV<15%.

     IL-2 INTER-ASSAY STATISTICS
  • Recovery

    IL-2 was spiked into five human serum samples, and then analyzed. The average recovery of IL-2 for serum samples is 97.58%.

     IL-2 RECOVERY

Customer Reviews
Writing Reviews

Recent Advances

 
Drug Development Progress
  • English Name:

    Interleukin-2

  • Category:

  • Approved Drugs:

    1 Details

  • Drugs in Clinical Trials:

    39 Details

  • Highest Development Stage:

    Approved

Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews