  • FAB

    1. Simple and fast operation - No complicated washing steps, significantly reducing time.
    2. High batch consistency - Strict control over raw materials and finished product quality, ensuring a stable supply.
    3. Accurate and reliable results - High sensitivity with minimal matrix effects.
    4. High throughput capability - Support multiple product specifications, ideal for high-throughput screening.
    5. Fast completion - Results in just 1 hour.
  • Product Specifications

    Assay Type
    Competition-TR-FRET
    Reactivity
    Human
    Regulatory Status
    RUO
    Assay Time
    1 hr
    Sample volume
    10 μL

  • Product Overview

    The Human OX40 / OX40 Ligand Inhibitor Screening Kit (TR-FRET) is based on a homogeneous (no wash) competition TR-FRET technology (Time-Resolved Fluorescence Resonance Energy Transfer) to screening for inhibitors of human OX40 binding to human OX40 Ligand within 0.5-1 hours. It can also be used as a universal detection tool to identify the ability of human OX40 to bind to human OX40 Ligand.

  • Storage

    1. Unopened kit should be stored at 2℃-8℃ upon receiving.

    2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.

    3. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    FRTP014-C01
    Human OX40 Ligand Protein Europium-chelate
    100 tests/500 tests
    FRTP014-C02
    FA Labeled Human OX40 Protein
    100 tests/500 tests
    FRTP014-C03
    Anti-OX40 Antibody
    10 μg/100 tests 50 μg/500 tests
    DB-04
    TR-FRET Sample Dilution Buffer, pH7.4
    50 mL/100 tests & 500 tests
    DB-05
    TR-FRET Detection Buffer, pH7.4
    50 mL/100 tests & 500 tests

  • Assay Principles

    This Human OX40 / OX40 Ligand Inhibitor Screening Kit (TR-FRET) is based on TR-FRET technology (Time-Resolved Fluorescence Resonance Energy Transfer). Use Europium-chelate labeled OX40 Ligand as the donor and a mixture of biotinylated OX40 and FA labeled streptavidin as the acceptor.

    — In the absence of inhibitors for human OX40 binding to human OX40 Ligand, the donor and acceptor are in close proximity due to the binding of human OX40 and human OX40 Ligand. Upon excitation with a specific light source, the donor emits a 620 nm signal, which is absorbed by the acceptor, resulting in a 665 nm emission.

    — In the presence of inhibitors that block the binding of OX40 to human OX40 Ligand, the donor-acceptor interaction is disrupted, preventing FRET from occurring.

    Assay Principles
  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Kunden haben auch angesehen

Data Display

  • Bioactivity-TR-FRET 

    Please refer to DS document for the assay protocol.

     OX40 TR-FRET

    Inhibition of Europium-chelate labeled Human OX40 Ligand Protein : FA Labeled Human OX40 Protein binding by Anti-OX40 Antibody
    Premix serial dilutions of Anti-OX40 Antibody (1:2 serial dilution, from 10 μg/mL to 0.0024 μg/mL (66.67-0.016 nM)) and FA Labeled Human OX40 Protein. Then add Human OX40 Ligand Protein Europium-chelate and incubate at room temperature (20℃-25℃) for 1 hours. Detection was performed with IC50 of 0.7388nM. The assay was performed according to the above-described Datasheet (QC tested).

User Reviews
Publish Comment

Frontier Progress

 
Drug Development Progress
  • English Name:

    Tumor necrosis factor receptor superfamily member 4

  • Category:

  • Listed Drugs Count:

    0 Details

  • Clinical Drugs Count:

    29 Details

  • Highest R&D Stage:

    Phase 3 Clinical

Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Kunden haben auch angesehen
  • Data Display
  • User Reviews
Kontaktieren Sie uns