PE-Labeled Human HLA-A*24:02&B2M Tetramer Protein (Peptide free)

Customer Reviews
Cat. No. / Size
Price
Availability
Qty
HLM-HP2H4-25ug
$410.00
In Stock - Delivery in 2-3 business days
HLM-HP2H4-200ug (100ug X 2)
$2350.00
In Stock - Delivery in 2-3 business days

Product Details

  • Synonyms

    HLA-A*2402 & B2M

  • Source

    PE-Labeled Human HLA-A*24:02&B2M Tetramer Protein (HLM-HP2H4) is expressed from human 293 cells (HEK293). It contains AA Gly 25 - Thr 305 (HLA-A*24:02) & Ile 21 - Met 119 (B2M) (Accession # AAA59600.1 (HLA-A*24:02) & P61769 (B2M) ).

    Predicted N-terminus: Gly 25 & Ile 21

    Request for sequence
  • Molecular Characterization

    PE-Labeled Human HLA-A*24:02&B2M Tetramer Protein is assembled by biotinylated monomer (HLM-H82W4) and PE-labeled streptavidin.

    Biotinylated Human HLA-A*24:02&B2M Monomer Protein is produced by co-expression of HLA and B2M. This Protein carries a polyhistidine tag at the C-terminus, followed by an Avi tag (Avitag™).

  • Conjugate

    PE

    Excitation Wavelength: 488 nm / 561 nm

    Emission Wavelength: 575 nm

  • Formulation

    Lyophilized from 0.22 μm filtered solution in PBS, 1% BSA, pH7.4 with trehalose as protectant.

    Contact us for customized product form or formulation.

  • Reconstitution

    Please see Certificate of Analysis for specific instructions.

    For best performance, we strongly recommend you to follow the reconstitution protocol provided in the CoA.

  • Shipping and Storage

    This product is shipped at ambient temperature.

    For long term storage, the product should be stored at lyophilized state at -20°C or lower.

    Please protect from light and avoid repeated freeze-thaw cycles.

    This product is stable after storage at:

    1. -20°C to -70°C for 12 months in lyophilized state;
    2. -70°C for 3 months under sterile conditions after reconstitution.
  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Bioactivity-ELISA

     HLA-A*2402 & B2M ELISA

    Immobilized PE-Labeled Human HLA-A*24:02&B2M Tetramer Protein (Cat. No. HLM-HP2H4) at 1 μg/mL (100 μL/well) can bind Anti-HLA class I Antibody, Human IgG1 (W6/32) with a linear range of 0.3-2 ng/mL (QC tested).

    Protocol
  •  HLA-A*2402 & B2M ELISA

    Immobilized PE-Labeled Human HLA-A*24:02&B2M Tetramer Protein (Cat. No. HLM-HP2H4) at 1 μg/mL (100 μL/well) can bind Anti-B2M Antibody, Human IgG1 with a linear range of 0.3-2 ng/mL (QC tested).

    Protocol
  • Evaluation of CAR expression

    FACS Analysis of Non-specific binding to PBMCs

     HLA-A*2402 & B2M CAR_T

    Non-specificity of PE-Labeled Human HLA-A*24:02&B2M Tetramer Protein (Cat. No. HLM-HP2H4) binding to CD4+ cells present in human PBMC. 5e5 of human PBMCs were simultaneously stained with Alexa Fluor® 700 anti-human CD4 Antibody and PE-Labeled Human HLA-A*24:02&B2M Tetramer Protein (1 µg corresponds to labeling of 5e5 cells in a final volume of 100 µL) and washed and then analyzed with FACS. Both Alexa 700 and PE positive signals was used to evaluate the non-specific binding activity to human CD4+ cells (Routinely tested).

    Protocol
  • FACS Analysis of Non-specific binding to PBMCs

     HLA-A*2402 & B2M CAR_T

    Non-specificity of PE-Labeled Human HLA-A*24:02&B2M Tetramer Protein (Cat. No. HLM-HP2H4) binding to CD8+ cells present in human PBMC. 5e5 of human PBMCs were simultaneously stained with FITC anti-human CD8 Antibody and PE-Labeled Human HLA-A*24:02&B2M Tetramer Protein (1 µg corresponds to labeling of 5e5 cells in a final volume of 100 µL) and washed and then analyzed with FACS. Both FITC and PE positive signals was used to evaluate the non-specific binding activity to human CD8+ cells (Routinely tested).

    Protocol

Customer Reviews
Writing Reviews

FAQ

  • product

    Can lyophilized proteins remain stable during room-temperature shipping or temporary room-temperature exposure?

    In general, lyophilized proteins remain stable during room-temperature shipping or temporary exposure to room-temperature conditions.


    Many ACROBiosystems recombinant proteins are supplied in lyophilized (freeze-dried) form. The lyophilization process effectively removes moisture from the product, helping reduce degradation-related reactions and improve protein stability during transportation and storage.


    To evaluate the stability of lyophilized proteins under normal temperature conditions, ACROBiosystems conducted a stability study on 11 representative lyophilized protein products at 37°C. The study demonstrated that these proteins maintained good quality stability after storage at 37°C for approximately 20 days. Based on these validation results, temporary room-temperature exposure during shipping or handling is generally not expected to have a significant impact on product quality or downstream application performance.


    To ensure optimal long-term stability, products should be stored according to the storage conditions specified in the product Certificate of Analysis (COA) upon receipt.


    Supporting Document


Recent Advances

 
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews
  • FAQ