Integrin α 4 β 7 : MAdCAM-1 [Biotinylated] Inhibitor Screening ELISA Kit

Customer Reviews
Cat. No. / Size
Price
Qty
EP-155-96tests
$770.00
ETA of in-stock products:2 business days

Product Details

  • Materials Provided

    ID
    Components
    Size
    EP155-C01
    High-bind Plate
    1 plate
    EP155-C02
    Human Integrin α 4 β 7
    25 μg
    EP155-C03
    Biotinylated Human MAdCAM-1
    10 μg
    EP155-C04
    Anti-Integrin α 4 β 7 Neutralizing Antibody
    20 μg
    EP155-C05
    Streptavidin-HRP
    5 μg
    EP155-C06
    Coating Buffer
    12 mL
    EP155-C07
    10xWashing Buffer
    50 mL
    EP155-C08
    Blocking Buffer
    50 mL
    EP155-C09
    Substrate Solution
    12 mL
    EP155-C10
    Stop Solution
    7 mL
    EP155-C11
    1mol/L CaCl₂
    1.5 mL
    EP155-C12
    1mol/L MgCl₂
    1.5 mL
    EP155-C13
    1mol/L MnCl₂
    1.5 mL

  • Product Overview

    Integrin α 4 β 7 : MAdCAM-1 [Biotinylated] Inhibitor Screening ELISA Kit is based on a competition-ELISA method, is used to screening for inhibitors of human Integrin α 4 β 7 binding to human MAdCAM-1. The kit is designed to provide a reliable solution for the screening of antibodies and small molecule inhibitors in the early stages, as well as QC release, to help researchers quickly screen and validate drugs, effectively improving research and development efficiency. It can also be used as a universal detection tool to identify the ability of human Integrin α 4 β 7 binding to human MAdCAM-1.

  • Reconstitution

    Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.

  • Storage

    Unopened kit should be stored at 2°C -8°C upon receiving. Find the expiration date on the outside packaging and do not use reagents past their expiration date.

    The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Typical Data 

    Please refer to DS document for the assay protocol.

     Integrin alpha 4 beta 7 TYPICAL DATA

    INHIBITION OF Integrin α 4 β 7: MAdCAM-1 [Biotinylated] BINDING BY ANTI-Integrin α 4 β 7 NEUTRALIZING ANTIBODY
    Serial dilutions of Anti-Integrin α 4 β 7 Neutralizing antibody (Catalog # EP155-C04) (1:1 serial dilution, from 5 μg/mL to 0.0098μg/mL) was added into Integrin α 4 β 7: Biotinylated MAdCAM-1 binding reactions. The assay was performed according to the protocol described below. Background was subtracted from data points prior to log transformation and curve fitting (QC tested).

  •  Integrin alpha 4 beta 7 TYPICAL DATA

    INHIBITION OF Integrin α 4 β 7: MAdCAM-1 [Biotinylated] BINDING BY selective α4 integrin antagonist
    Serial dilutions of selective α4 integrin antagonist (1:1 serial dilution, from 10 μg/mL to 0.1526μg/mL) was added into Integrin α 4 β 7: Biotinylated MAdCAM-1 binding reactions. The assay was performed according to the protocol described below. Background was subtracted from data points prior to log transformation and curve fitting (Routinely tested).

Customer Reviews
Writing Reviews

Recent Advances

 
Drug Development Progress
  • English Name:

    Integrin alpha-4/beta-7

  • Category:

  • Approved Drugs:

    4 Details

  • Drugs in Clinical Trials:

    14 Details

  • Highest Development Stage:

    Approved

Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews