Product Details

  • Items
    Details
    Detection Method
    Chemiluminescence
    Product Type
    Magnetic Beads (Monoclonal anti-FITC antibody)
    Quantity Size
    10mg / 100mg
    Physical Appearance
    lyophilized powder mixture
    Particle size
    2.8µm
    Beads Surface
    Hydrophilic
    Binding Capacity
    1-2μg FITC Antibody / mg beads
    Emission Wavelength
    Measured relative light units (RLU) at 430 nm
  • Product Description

    The Anti-FITC Antibody coupled Magnetic Beads are 2.8 µm superparamagnetic particles covalently coupled to a highly affinity Monoclonal anti-FITC antibody. The beads can be used to capture the FITC Antibody in Chemiluminescence procedures. The Anti-FITC Antibody coupled Magnetic Beads is easy to capture the FITC labeled proteins, and the bounded proteins have no activity lost, this ready to use products could greatly save your protein coupling time and hassle, and help us get the best performance and highly reproducible results.

  • Application

    The Anti- FITC Antibody coupled Magnetic Beads is used to capture the FITC Antibody, it can combination with Acridinium markers in chemiluminescence technology, The Acridinium ester markers such as Anti-Human IgG Antibody-Acridinium ester can capture the antibodies , this allows detection of antigen and antibody binding or antibody screening.

  • Reconstitution

    See Certificate of Analysis (CoA) for detailed instruction.

  • Storage

    Upon receipt, please store the Beads at -20℃. The shelf life is 1 year at -20 ℃.

    Please avoid more than 3 freeze-thaw cycles once reconstitution, immediate use after reconstitution is highly recommended.

  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Kunden haben auch angesehen

Data Display

  • Bioactivity-MPCLIA

     Anti-FITC MPCLIA

    Immobilized 0.05 μg /Test of FITC-Labeled Human BCMA, His Tag(Cat. No. BCA-HF2H1) to the Anti-FITC Antibody coupled Magnetic Beads (recommended for MPCLIA) (Cat. No. MPC-A009) (10 μg beads/Test), incubated with 100 μL /Test of Monoclonal Anti-Human BCMA Antibody, Human IgG1 (Cat. No. BCA-M26) at increasing concentration coupled to the Anti-Human IgG Antibody-Acridinium ester(Cat. No. AHG-Y69, 0.04 μg /Test). Detection was performed with sensitivity of 0. 98 ng/mL in Magnetism particulate chemiluminescence immunoassay (MPCLIA) (KEYSMILE, SMART 6500S) (QC tested).

    Protocol
  •  Anti-FITC MPCLIA

    The MPCLIA assay shows that Anti-FITC Antibody coupled Magnetic Beads (recommended for MPCLIA) (Cat. No. MPC-A009) is stable at 37°C for 10 days.

  •  Anti-FITC MPCLIA

    The MPCLIA assay shows that Anti-FITC Antibody coupled Magnetic Beads (recommended for MPCLIA) (Cat. No. MPC-A009) is stable after freezing and thawing 3 times.

  •  Anti-FITC MPCLIA

    The MPCLIA assay shows that Anti-FITC Antibody coupled Magnetic Beads (recommended for MPCLIA) (Cat. No. MPC-A009) is stable at 37°C for 10 days.

User Reviews
Publish Comment

FAQ

  • product

    Can lyophilized proteins remain stable during room-temperature shipping or temporary room-temperature exposure?

    In general, lyophilized proteins remain stable during room-temperature shipping or temporary exposure to room-temperature conditions.


    Many ACROBiosystems recombinant proteins are supplied in lyophilized (freeze-dried) form. The lyophilization process effectively removes moisture from the product, helping reduce degradation-related reactions and improve protein stability during transportation and storage.


    To evaluate the stability of lyophilized proteins under normal temperature conditions, ACROBiosystems conducted a stability study on 11 representative lyophilized protein products at 37°C. The study demonstrated that these proteins maintained good quality stability after storage at 37°C for approximately 20 days. Based on these validation results, temporary room-temperature exposure during shipping or handling is generally not expected to have a significant impact on product quality or downstream application performance.


    To ensure optimal long-term stability, products should be stored according to the storage conditions specified in the product Certificate of Analysis (COA) upon receipt.